• Documentation
  • Contact Us
  1. Home
  2. Digital Tools
  3. LOGSTOR Design Tool: Single Pipe

LOGSTOR Design Tool: Single Pipe

LOGSTOR Design Tool offers the possibility to calculate axial stress level, expansion at bends and branches, location and amount of expansion cushions, and other calculation functions needed to make a complete static layout of a pipe system.

Discover The Potential

Scroll For More

All calculation functions are available for both single pipe and TwinPipe and when the calculation results are complied with, a minimum design life of 30 years is ensured. If the calculation results exceed the allowable values, a warning is shown on the screen.

The calculation results are accompanied by graphics showing the location and number of expansions cushions. Calculations can be exported to a PDF file and saved. LOGSTOR Design Tool is based on the calculation methods and the design rules given in LOGSTOR Design Manual, which is based on optimization of technical and economic aspects.

By using the Design Tool, which complies with the LOGSTOR Design Manual, and by taking local conditions into account, it is ensured, that the designed bonded pipe system is on the level with the static requirements in the European standard EN13941. This compliance means that dimensions up to and including DN 300 can be designed with this Design Tool as documentation.

The Design Tool calculations are only guiding for dimensions larger than DN300.

Go to LOGSTOR Design Tool: Single Pipe

Click the button below to go directly to the LOGSTOR Design Tool: Single Pipe.
Take me there

How does it work?

LOGSTOR Design Tool: Single Pipe

1. Select pipe calculation type

Start by selecting the type of pipe calculation you want to calculate foam pads for: 80-90° bends, <80° bends, Z-bends, U-bends, or branches.

LOGSTOR Design Tool: Single Pipe

2. Input your data

Enter your system design parameters. Calculations for foam pads are based directly on the values you provide in this step.

LOGSTOR Design Tool: Single Pipe

3. Add pipe lengths

Enter pipe lengths as the distance to the virtual anchor (total length between expansion bends divided by 2) for balanced expansion on both sides of the anchor.

LOGSTOR Design Tool: Single Pipe

4. View results

The tool calculates expansion and foam pad requirements. Warnings are displayed if the calculated expansion exceeds acceptable limits.

LOGSTOR Design Tool: Single Pipe

5. Multiple calculations

Use the multiple calculations table to create up to 10 calculations on a single page. Print and save them for easy reference.

Talk to us

To get in touch please contact us by using the details below or visit our contact page here

Head office

LOGSTOR Denmark Holding ApS
Danmarksvej 11
DK-9670 Løgstør
Denmark

Call us

For any general enquiries via phone:

+4599661000

Email us

For any general enquiries via email:

Logstor@kingspan.com
Home
Products
Segments
Services
Contact
Documentation
About Us
News
Career
Social media
Facebook
LinkedIn
YouTube
Legal Information
Anti-Bribery and Anti-Trust
Cookie Policy
Code of Conduct
Corporate Social Responsibility
Modern Slavery Statement
Privacy Notice
Sales & Supply Conditions
Whistleblower

LOGSTOR Denmark Holding ApS — Danmarksvej 11, DK-9670, Løgstør, Denmark